0% Complete
صفحه اصلی
/
هشتمین کنفرانس بین المللی فناوری و مدیریت انرژی
Asymmetric resonance phenomenon in transmission lines equipped with compensation reactors and study about destructive effects
نویسندگان :
Mohsen Khaleghi
1
Mohammad Hossein Norouzi
2
1- شرکت برق منطقه ای زنجان
2- دانشگاه تبریز
کلمات کلیدی :
Overvoltage،Asymmetric Resonance،Shunt Reactor،Compensation Lines،Transposed Lines،Ferranti Effect،Passive Fault
چکیده :
Considering the inevitable nature of asymmetric conditions in the use of the power system, such as the geometrical arrangement of the phase conductors in single-circuit (horizontal type) and double-circuit (vertical types) in the transmission towers, and considering the necessity of preventing the occurrence of accidents that damage the equipment itself and the grid, studies for transmission lines compensated by the shunt reactor in the conditions of electrical and geometric asymmetric operation and using practical solutions to prevent the occurrence of temporary overvoltage on the equipment connected to the transmission line has been carried out which is necessary for the planning and development of transmission and operation as well. This necessity is raised for compensated lines after the implementing the construction of transmission stations and power plants (PP) and inlet-outlet lines while the condition of the line compensator has not been reviewed in the new conditions. In this article, before solving the problems of evaluating the desirability of compensated lines from the point of view of electrical resonance stability study (ENRS) / (diagnosis of resonance, pseudo-resonance, and Ferro-resonance conditions) and presenting possible solutions to provide desirability criteria, the necessity of using a shunt compensator in transmission lines is proposed to prevent various serious damages and financial losses and the multiple simulation results verified the vital role of the shunt compensator.
لیست مقالات
لیست مقالات بایگانی شده
An optimized H6-type single-phase PV inverter with bi-directional quasi-diode clamping
Mohammad Farahani - Mohammad Ali Shamsi-Nejad
A Bi-Level Optimization Model for Citizen Energy Communities Towards Sustainable Development: A Stackelberg Game Theory Approach
Sahar Mobasheri - Masoud Rashidinejad - Amir Abdollahi - Mojgan MollahassaniPour - Sobhan Dorahaki
Optimal Energy Management in the Electric Vehicles Parking Lot Equipped with Renewable Energy Source
Mohammad Hadian-Abbasalikashi - Meisam Jafari-Nokandi
بررسی میزان مصرف انرژی در سیستمهای گرمایشی مبتنی بر تابش و جابهجایی در یک ساختمان نمونه
عسگر مینایی - حامد احدنژاد - فرهاد صادق مغانلو - محمد عباداللهی
بررسی مصرف برق ناشی از استخراج رمزارزها در شبکه برق منطقهای خوزستان
رضا عظیمی - کیومرث زمانی - امید سروری
Traffic-Constrained Multiobjective Placement of PEV Parking Lots with Flexible Charging Control in Power Distribution Systems
Meysam Mohammadi landi - Ehsan Shalooyi
A Novel Design Approach for Multi-Carrier Energy Systems Incorporating Self-Sufficient Microgrids
Narges Daryani - Kazem Zare - Sajjad Tohidi - Josep Guerrero - Najmeh Bazmohammadi
بازآرایی شبکههای توزیع برای افزایش حد بارگذاری بهمراه جایابی و مقداردهی خازن در شبکه
جواد رضایی - رسول کاظم زاده
بهرهگیری از کامیون احتراق داخلی برای ایجاد پایگاه درمانی اضطراری
مهرداد فروزان - محمدصادق قاضیزاده
Application of Artificial Neural Network in predicting building’s energy consumption
Rahim Zahedi - Alireza Aslani - Arash Gitifar - Omid Noudeh Farahani - Hossein Yousefi
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 41.2.0