Asymmetric resonance phenomenon in transmission lines equipped with compensation reactors and study about destructive effects
نویسندگان :
Mohsen Khaleghi
1
Mohammad Hossein Norouzi
2
1- شرکت برق منطقه ای زنجان
2- دانشگاه تبریز
کلمات کلیدی :
Overvoltage،Asymmetric Resonance،Shunt Reactor،Compensation Lines،Transposed Lines،Ferranti Effect،Passive Fault
چکیده :
Considering the inevitable nature of asymmetric conditions in the use of the power system, such as the geometrical arrangement of the phase conductors in single-circuit (horizontal type) and double-circuit (vertical types) in the transmission towers, and considering the necessity of preventing the occurrence of accidents that damage the equipment itself and the grid, studies for transmission lines compensated by the shunt reactor in the conditions of electrical and geometric asymmetric operation and using practical solutions to prevent the occurrence of temporary overvoltage on the equipment connected to the transmission line has been carried out which is necessary for the planning and development of transmission and operation as well. This necessity is raised for compensated lines after the implementing the construction of transmission stations and power plants (PP) and inlet-outlet lines while the condition of the line compensator has not been reviewed in the new conditions. In this article, before solving the problems of evaluating the desirability of compensated lines from the point of view of electrical resonance stability study (ENRS) / (diagnosis of resonance, pseudo-resonance, and Ferro-resonance conditions) and presenting possible solutions to provide desirability criteria, the necessity of using a shunt compensator in transmission lines is proposed to prevent various serious damages and financial losses and the multiple simulation results verified the vital role of the shunt compensator.
لیست مقالات
لیست مقالات بایگانی شده
استفاده از انرژی خورشیدی جهت تامین انرژی الکتریکی ساختمانها – مطالعه موردی: ساختمان آموزشگاه پروین اعتصامی هشترود
ابراهیم آقائی - بهزاد فریدونی - بهرام بالازاده
Developing Internet of Behavior Approach in Smart Grids for Optimal Parking lots Allocation Problem
Reza Zamani - Farid Moazzen
امکان سنجی کاهش مصرف انرژی و افزایش تبادل حرارت در مبدل پوسته و لوله با استفاده از لوله ها با سطح فرورفتگی
مسعود دربندی - محمد صالح عبدالله پور - کاظم مشایخ
Energy Modeling: A Comparison of Statistical Methods and Artificial Neural Networks for Electricity Load Forecasting
Melika Asgharzadeh - Rahim Zahedi - Sahand Heidary
Disease Diagnosis and Data Protection System for IoT-based Wearable Sensor Network
Erfan Haghighat khah - Mehdi Golsorkhtabaramiri
Reliable Operation of V2G-Equipped Parking Lots Based on Probabilistic Mobility Patterns of Plug-in Hybrid Electric Vehicles
Hossein Shahinzadeh - Jalal Moradi - Ahmad Hafezimagham - Gevork B. Gharehpetian - Mohamed Benbouzid - S.M. Muyeen
بررسی مشخصه انتقال حرارت در یک کلکتور خورشیدی دارای نوار پیچشی با استفاده از نانوسیالات گرافن و اکسید آلومنیوم
محمد صادق عابدی نژاد - دنیا صباغچی فیروزآباد - علیرضا تیموری
به کارگیری آیین نامه های اجرایی قانون اصلاح الگوی مصرف انرژی، اولویتی فراموش شده در رفع ناترازی انرژی در ایران
سیده لیلا کرمانی - سید ابراهیم فکاری
مدیریت زنجیره تأمین پایدار انرژی های تجدیدپذیر زیستتوده
لیلا اصلانی - عاطفه حسن زاده - فاطمه صبوحی
مروری بر انرژی برقابی با تاکید بر برقابیهای کوچک
منصوره ارجمندی - سمیه نهاوندیان - مازیار دهقان
بیشتر
ثمین همایش، سامانه مدیریت کنفرانس ها و جشنواره ها - نگارش 44.0.1